Is Your Public Address System's Sound Clear

The voice notification in the public address system must can be understood by people, otherwise it is just noise pollution. Sometimes the unclear voice notification may also cause legal fallout.


How to use the public address system effectively:

1. Make sure that all installed amplified speakers have the same polarity to ensure that the given power has the highest SPL output.

2. Test whether each amplified speaker is in place. It can be tested by using a 19kHZ high-pass filter, so that it will not disturb the public.

3. Verify whether the number of amplified speakers connected together matches the specifications of the drive distribution amplifier. For this, you will need an impedance meter. Some impedance meters will provide a direct readout of the power of the connected speakers.

4. Verify the reverberation time of your environment. If necessary, let the architect or construction company be aware of the necessity of room treatment, and realize that the reverberation time depends on the frequency and should be measured in the entire voice frequency band.

5. Verify the distortion level of the electrical system and determine the damaged signal processor or amplifier. For this, you will need a pure sine wave blending distortion analyzer.

6. Know exactly which level your background noise is. If possible, you will need to adjust the PA audio system to 10 to 15dB above this level for transmission. For this, you need an SPL meter with averaging function. Remember that the sharpness will start to drop again at an absolute level above 90 decibels, because at such a high level, our ears will become less sensitive.

7. If the operator uses a PA system microphone to broadcast an evacuation notice, the STI-PA test should be performed with a calibrated audio signal source.

8. After you optimize all these moving points, you do not need to use the STI-PA instrument to finally measure the speech intelligibility. If operating properly, you will announce the 0.5 minimum requirement of the evacuation system at all test points.

Related News
  • Several Points for Attention in Designing Digital Public Address System

    Several Points for Attention in Designing Digital Public Address System

    April 24, 2019(1) We should understand the needs of users and avoid wasting investment by using network digital broadcasting for digitalization.(2) Understanding the design parameters of the network system to be bu...view
  • An Overview of Type D Amplifier

    An Overview of Type D Amplifier

    April 24, 2019The type d amplifier drives the amplifier of the loudspeaker by controlling ON/OFF of the switching unit. The type d amplifier was first introduced in 1958, and it has gradually become popular in rece...view
  • The Benefit of Ceiling Speaker

    The Benefit of Ceiling Speaker

    November 4, 2020In truth, the ceiling speaker has enjoyed a long history. However, many people who don’t know it well still consider that ceiling speaker is not professional enough.In reality, as a result of the low...view
  • Coverage of Outdoor Commercial Audio Speakers

    Coverage of Outdoor Commercial Audio Speakers

    January 14, 2021Outdoor commercial audio speakers have the characteristics of water-proof,moisture-proof anti-corrosion, wind resistence and sun resistence. Their applicable scope is so broad that they are applied to...view
  • What Is Digital Radio Accessibility?

    What Is Digital Radio Accessibility?

    January 9, 2019There is a report on digital radio access. The report describes the current developments in digital radio technologies and applications. Current digital infinite power technology can help people with ...view
  • Advantages and Disadvantages of Active and Passive PA Loudspeakers

    Advantages and Disadvantages of Active and Passive PA Loudspeakers

    April 24, 2019Traditional pa system horn speakers are centered on one or more power amplifiers, which are usually installed in the equipment rack. Although they are not as popular as before, the traditional large-s...view
chat
  • TEL:+86-13076829269
  • FAX:
  • EMAIL:info@rh-audio.net
  • ADDRESS:No. 601-2,602,603,Building 11,Zone 2,Wanyang S&T Park,Beijiao Town,Shunde District,Foshan City,Guangdong Province,China